Main Menu
Publish Date
23 November 2026
Hussein Naji BE(Hons) MIEAust CPEng NPER – Director, Horizon Engineers
The short answer: not automatically. An existing roof drainage system generally only has to meet the standard that applied when it was built. But the moment someone does plumbing work on it, even replacing a gutter, that work has to comply with the current Plumbing Code. And strata law, council orders and insurers can push you to upgrade anyway.
We get this question every time an older building floods during a storm. Owners corporations, facility managers, insurers and builders all ask a version of it:
The answers sit across three documents that rarely get read together: the Building Code (NCC Volumes One and Two), the Plumbing Code (NCC Volume Three), and state legislation. This article walks through them using NSW, where most of our work is.
1. The Building Code is not retrospective. NCC Volume One (F1D3) and Volume Two (H2D2, H2D6) call up AS/NZS 3500.3 as the Deemed-to-Satisfy route for roof drainage. But the ABCB is clear that the NCC applies mainly to new buildings and new building work. It doesn’t generally reach back into an existing building unless that building is being altered, extended or changed in use.
2. The Plumbing Code is different. NCC Volume Three, the Plumbing Code of Australia (PCA), covers plumbing and drainage in new and existing buildings, and applies whenever plumbing work is carried out. Roof drainage is plumbing work. This is the part most people miss.
3. NSW law makes the PCA binding on the person doing the work. Under section 7 of the Plumbing and Drainage Act 2011 (NSW), the responsible person for plumbing and drainage work must make sure the work complies with the PCA. NSW Fair Trading is the regulator. The PCA’s Deemed-to-Satisfy path for roof drainage is AS/NZS 3500.3.
4. Which edition? AS/NZS 3500.3:2025 was published on 17 April 2025, with updated overflow and eaves gutter provisions. But NSW is still on NCC 2022 and doesn’t adopt NCC 2025 until 1 May 2027. So for NSW work today, comply with the edition the PCA currently references. Our advice: check your design against 2025 as well, because overflow provisions are where audits fail and the newer edition reflects current thinking.
Put simply: the building is judged against the code of its day. The work is judged against the code of today.
The detail behind each branch:
| Situation | Must the current AS/NZS 3500.3 be met? | Why |
|---|---|---|
| Nothing is being changed and the system works as built | No | Assessed against the code at the time of construction. The NCC isn’t retrospective |
| Gutters, downpipes, sumps or box gutters replaced or repaired | Yes, for the work done | The PCA applies to plumbing work in existing buildings. The untouched parts don’t have to be upgraded |
| Alterations or additions add roof area or flow | Yes for the new work, and for any existing element that now takes the extra flow | New building work must comply with the NCC |
| Change of use | Depends on the consent conditions | NSW upgrade-on-alteration powers focus on fire safety and structural capacity, not drainage, unless Council conditions it |
| Strata building where drainage has failed or leaks | Must be repaired (s106, Strata Schemes Management Act 2015) | The duty is to repair, not to upgrade. But the repair is plumbing work, so the repaired parts must meet the current PCA |
| Council issues a development control order | Whatever the order requires | Orders under Schedule 5 of the EP&A Act can require specific works |
| Insurer, lender or purchaser asks for compliance | Not legally, but practically yes | A contractual or commercial requirement, not a code one |
The pattern: compliance is triggered by work, failure or an order, never by age alone.
Horizon carries out roof drainage compliance assessments on existing commercial and industrial buildings, mostly from roof condition audits commissioned after a leak or flood. The same pattern shows up again and again:
The practical takeaway for owners: you may not be required to upgrade, but a targeted fix found by a proper assessment is far cheaper than the next flood claim.
No, not by age alone. An existing system is judged against the standard it was built to. But any new plumbing work on it must comply with the current Plumbing Code and AS/NZS 3500.3, and owners must keep it working.
Horizon Engineers carries out roof drainage compliance assessments on existing commercial, industrial and strata buildings across Sydney. We check gutters, box gutters, sumps, downpipes and overflows against AS/NZS 3500.3 and tell you what actually needs fixing. Contact us for a fee proposal.
Disclaimer: This article is general in nature and focused on NSW. It is not advice for any particular site. Requirements vary by state, consent conditions and strata by-laws. Get site-specific engineering and legal advice before relying on it.
Hussein Naji, Director, Horizon Engineers
Resources